CV, E And I Engineer With Oil And Gas Experience

Available
Serial No: 41512
Skills keywords: 
Current location:  Muscat Governorate, Oman - View on map
Nationality: Indian
Spoken languages: english

Qualifications

Degree in Electrical and Electronics Engineering (2008 December)
Vidya Academy of Science and Technology Thrissur, Calicut University, Kerala

 

Certifications

• Compex Competence Training in Ex 01, Ex 02, Ex 03 and Ex 04 – Petrotech, Qatar

• Atex Explosion Protection systems – Theory and Practical ( IEC 60079 )

• IRCA approved QMS ISO 9001:2008 Lead auditor ( TUV India Pvt Ltd. )

• Certified automation Engineer course from Prolific systems coimbatore, which includes,

PLC, SCADA, DCS, INDUSTRIAL DRIVE AUTOMATION, INSTRUMENTATION

• AUTOCAD 2010

 

IT Skills

Windows 7, Windows XP, MS Office

 

Languages

English, Hindi, Malayalam, Tamil

 

Experience Summary

 Currently working with Ray International L.L.C, Muscat as Project in charge, E&I Engineer and Hazardous area Inspector (Ex Inspector) in Oil and Gas (PDO) areas
From May-2011.

 Responsibilities:-

• Inspection on installation of equipment and associated accessories in potentially explosive hazardous atmosphere.

• Risk Based Inspection of Ex equipment following the SMS.

• Maintain the Check list as per the RBI reports.

• Reviewing & approving EPC Contractor’s inspection & test plan, work procedures and method statements.

• Verify the design drawings and inspect the same after installation.

• Inspection and quality check based on the Client standards.

• Carry out the site activities with following complete HSE standards.

• Carries out periodic safety audits.

• Planning and Executing the Shutdown activities of Oil and Gas Stations and Power station for doing the Ex Rectification activities.

• Inspection and Maintenance of LV and HV motors, Cranes, Light fittings, Socket outlets, Fire & Gas systems and Cooler fans in the Oil and Gathering stations.

• Monitoring the new commissioning projects and certify the same.

• Issuing Non Conformance & Site Inspection Reports for non-compliance activities against the approved quality procedures, inspection test plans, codes & standards and closed out on satisfactory corrective / preventive actions.

• Obtained Certified Electrical Personnel (CEP) and Permit to Work Applicant Authorization from PDO.

• Preparing work permits for doing the Inspection and repair activities on hazardous areas.

• Project in Manager for the Ex Inspection and Rectification works in PDO.

• Preparing quotations for new job and work contracts with the client.

• Familiar with the Usage of software EPICOR in the network.

• Preparing Purchase orders, Material requisitions and monitoring of material transfer.

• Coordinates all the Ex inspection activities and audit the inspection reports prepared by other inspectors.

• Project Manager for replacement of porcelain insulators with Silicon insulators in 220kV and 132kV transmission lines

• Improvement of tower footing earth resistance of Transmission towers

• Fixing conductor marking lights for 220kV and 132kV transmission lines

• Internal audits in the company as per ISO 9001:2008

 

Areas and Projects Worked :-

 Petroleum Development of Oman ( PDO )
Ex inspection and rectification in Oil and Gas gathering stations, Power Generating stations, Gas wells Ex Inspection of Qarnalam Power station Phase 3

 Oman LNG
Ex inspection and Rectification in Train-1,during shutdown.

 STST.
Ex inspection of Y2DC Yibal GGP, Haban Liquid Handling project-Yibal GGP, GG Well test-Qarnalam, SNMG Qarnalam

 L & T Oman
Ex Inspection in Lekhwair Gas Field Extension Project.

 Al Hassan
Ex Inspection in Amal HRSG Project

 GS Engineering & Construction
Ex Inspection of SNDC Phase 1 Project Qarnalam.

 Gulf Petrochemical Services
Ex Inspection of Amine off-plot project.

 Galfar

Ex Inspection of Khulud wells- Fahud,Yibal

 Oman Electricity Transmission Company
Replacement of Porcelaine insulators with silicon Insulators in 220kV and 132kV transmission lines.

Improvement of tower footing Earth Resistance value in Transmission towers ( 220kV )

Installation of inductive conductor marking lights in 132kV and 220kV transmission towers.

 

One year as Trainee Engineer at S.E.P.R Refractories India Ltd. Kerala, India

Responsibilities:-

• Operation and maintenance of EHV substation, Vertical rotary surface grinder, EO Cranes , Arc furnace , milling machines , diesel generator

• Inspection of Energy monitoring system

• Variable frequency drive :- Telemecanique, ABB, Siemens

• Installation and testing of various panels, such as EOT cranes control and power panels, arc furnace control panel etc., as per the approved procedures inside the plant.

• Installation and testing of Circuit breakers, Current transformers, surge arrestors and Isolators as per the Quality plan.

 

 6 months as supervisor at Prime Electrical Services, Cochin, Kerala, India

Responsibilities:-

• Planning and designing Electrical schematics for Communication towers,

• Responsible for the material supply and Labor supply at the site.

• Acquiring certificates and reports from various govt. departments such as Electricity board ,electrical Inspectorate etc.

 

 






popup-img